HewTech Electronics LLC has developed a controller to detect the phase-change from vapor to liquid for Liquefied Natural Gas (LNG) filling stations.

LNG-CONT.jpg (18906 bytes)The Model RTS-100 control monitors a sensor positioned in the fill line, monitoring the flow of LNG.  It provides a visual indicator and a relay change when liquid is detected.  The relay transition sends a signal to the main fill controller, indicating Liquid has reached the sensor.  The FILL solenoid is opened & the VENT solenoid is closed, and fuel is then routed to the vehicle fuel-tank through the FILL nozzle.

The sensor is made from 1/8" diameter 304 Stainless Steel tube & Teflon cable provides immunity to the harsh environments.  The control is contained within an IP54/65 (NEMA4/5 Dust & moisture proof) enclosure with a sealed tinted cover.   This allows visual indication of the status LED's at the control location.  A 10-amp relay is provided.

Calibration is a one-time operation and no special instruments are required.  Only a small screwdriver is necessary for adjustment while monitoring the STATUS LED's.  No more matching specialized sensors to instruments.  

Power is 120VAC @ 3-watts, transformer isolated.  The control provides transformer coupled, low-voltage DC power to the sensor.   Sensors are available for custom lengths & special mounting configuration. 

This product represents what can be developed for your specific application)

For additional LNG information "CLICK HERE"

BACK TO HEWTECH PRODUCTS PAGE

 

CONTACT US

Copyright 1998
HewTech Electronics LLC
Last Updated: December 31, 2011

WEB HOSTING BY Hosting@BadgerTech.net